FLOW
V-cone
DESCRIPTION: Fixed geometry differential pressure gauge that allows a very low pressure drop to be obtained. It is used when the minimum upstream and downstream straight lengths are required and when high turndown is available. The new designs of differential pressure transmitters, increasingly precise and capable of integrating a greater number of process variables, confirm the validity of this type of meter.
Applications
- Measurement in gases and liquids with particles.
- Viscous and corrosive fluids.
- For all types of industrial plants such as:
- Energy generation.
- Chemical and petrochemical industries.
- Renewable energy.
- Food industry.
- Water treatment.
Design
- Calculation standards: ISO 5167-5
- Materials: Low alloy, stainless steel and high alloys.
- Size of Manufacture: 2” – 20”
- Flange Finishes: RF, FF, RTJ
Specifications
- Beta: 0.45 – 0.75
- Reynolds: 8×104 – 1.2×107
- Accuracy: 5%
Notes
– Maximum operating temperature: According to the rating of the flanges, pipe thickness and materials used.
– Maximum operating pressure: According to the flange rating, pipe thickness and materials used.